The most common types of direct burial cable used in residential projects are underground service entrance use and underground feeder uf.
Underground electrical service entrance.
Are underground feeds better than overhead feeds.
When dealing with service entrance cables on new homes the question often comes up about underground and overhead feeders.
The entrance cable must have at least 18 inches of excess wire left past the weather head to allow connection of the service wire.
Weather head must be a minimum of 18 inches from top of the.
Decide how much digging you re prepared to do which determines the type of wire you need to use.
For a 6 in deep trench use galvanized rigid metal electrical conduit with individual conductors inside.
Instead of overhead aerial cable feeding an overhead service conduit an underground service is fed by underground direct burial cable.
The southwire company 500 ft.
The service lateral cables must be protected in the ground by conduit until they reach a depth of four feet.
Type use cable is usually black and is most often used for buried lines that bring power from the utility s transformer to individual houses.
Underground cable for running electrical power to a remote location can be installed at different depths depending on the type of conduit and type of wire used.
2 2 2 4 al ser the southwire company 500 ft.
Underground service entrance feeds are fed like their names imply underground.
See below for our guide for meter base and weather head installation.
See below for our assembly guide for meterbase for underground service.
Residential electrical code examples for underground.
2 2 2 4 al ser service entry electrical cable can be used in wet and dry locations up to 90 c or 194 f.
If you are sufficiently confident of your wiring skills that you would feel comfortable adding an electrical circuit indoors then running a circuit to a.
Nec 300 5 underground wiring conduit identification underground service laterals shall have their location identified by a warning ribbon placed in the trench at least 12 inches above the underground installation.
Extending electrical service to a detached garage or other outbuilding isn t much different than adding a circuit inside the house with one important exception running underground cable.
The short answer is yes underground is preferable to overhead mostly due to the protection feeders get from being buried but underground service equipment can be much more expensive than similar overhead feeds and.
This method has become the choice of many replacing the unsightly overhead feeds.
With underground service the service lines between the utility transformer and the house are known as the service lateral and the service entrance conductors often travel up to the service panel rather than down from the roof.
This cable is primarily used as a panel feeder in multiple unit dwellings.