Downside to using type uf in conduit is the need for larger conduit more money and the significantly more work to install for in my opinion zero gain.
Type uf cable in conduit.
Table 310 17 says that conductors in free air can have a higher ampacity than conductors in conduit see 310 16.
Type of wiring method or circuit.
Electrical cable depth options.
Out of an underground trench that is 24 inches deep.
Type uf cable is the most commonly used nonmetallic cable for residential outdoor wiring runs.
But it can be difficult to fish cable through conduit unless the conduit is at least 3 4 inch in diameter.
In most cases this also applies to interior wiring projects as well except where subject to physical damage such as where the cable exits the ground.
More about electrical wiring.
Decide how much digging you re prepared to do which determines the type of wire you need to use.
For a 6 in deep trench use galvanized rigid metal electrical conduit with individual conductors inside.
Direct burial cable can be run inside the conduit to add additional protection to any electrical system.
Although not commonly done it is allowable to run uf cable but not nm cable through metal or pvc conduit in an underground application.
Running uf cable through metal or pvc conduit.
Electrical wire for the home.
Complete listing of electrical wire types.
If you are going to run conduit anyway it is best to then run type thwn or thhn thwn individual conductors.
More heat 310 16 2 uf cable in raceway cable or earth on allowed 95 amps.
Uf cable in conduit.
Much much easier to work with than uf.
Underground cable for running electrical power to a remote location can be installed at different depths depending on the type of conduit and type of wire used.
2 rigid metal conduit or intermediate metal conduit.
Uf cable can be direct buried without conduit with a minimum of 24 inches of earth cover.
Type uf cable is usually gray and comes in rolls that look like standard.
Wiring buried inside rigid metal rmc or intermediate metal imc conduit must have at least 6 inches of earth cover.
Wiring in pvc conduit must have at least.
As mentioned above uf electrical wire does not require the use of conduit or any other type of protective covering.
This type of cable is designed to withstand direct exposure to the soil and moisture and is rated for wet dry and damp environments.
3 nonmetallic raceways listed for direct burial without concrete encasement or other approved raceways.
Location of wiring method or circuit.
Electrical wire for the home.
For example 310 17 60 degree 2 uf cable in free air is good for 110 amps.
Then conduit normally electrical pvc is required.
Where a pvc conduit may sleeve the uf cable as it leads up out of the ground to an electrical box.